Vol.7-2 |
|
石川県加賀市における落雷災害について −l986年12月28日の事例−
A Cloud-to-Cround Discharge Disaster in Kaga City of Ishikawa Prefecture
on 28 Dec. 1986 |
道本 光一郎*
Koichiro MICHIMOTO* |
Abstract
Winter thunderstorms have often occurred in Ishikawa prefecture. In this
report, a case of the cloud-to-ground discharge on December l986 is analyzed
according to the data of“The Thunderstrm Detection Systems” in the Komatsu
air base near the cloud-to-ground discharge point.
The followings were concluded;
1) The cloud-to-ground discharge occurred in the area of surface positive
strong electric field. (over 20 kV/m)
2) And this discharge point was located in the leading edge of the strong
radar echo.(over 50 dBZ)
3) By using the data of field mills and weather radar, we can forecast
hazards of cloud-to-ground discharges befor about half an hour.
【キーワード】:落雷, レーダーエコー, 雷電探知システム
*防衛大学校地学教室
Inst. of Ceosciences & Astronomy, The National Defense Academy
|